Abstract

Objective: compare the values of the Bennett angle measured by an average value articulator with the ones

measured by a 64 slices Computed Tomography (CT).

Methods: we have studied a patient aged 72. Maxillary and mandibular impressions were obtained from the patient and placed on the average value articulator using wax-ups and a facial arch in order to perform the Bennett angle measurations by such device. CT measurements were carried out using tient in the correct mandibular position.

Results: our study has demonstrated that the measure ments of the Bennett angle obtained with the average value articulator are consistent with the ones obtained with the 64 slices CT.