The aim of the work. The mandibular canal, if it is affect-

ed by different illnesses, often shows typical radiological

changes, made up of widespread hypodensity, an in-

crease in its diameter and disappearing walls. This study

aims to verify the reliability of such radiological signs in

the cases of later post-operative lesions of the mandiblu-

lar canal.

Materials and method. The study includes 16 patients, 9

males and 7 females, with an average age of 54 years,

who underwent an operation to rehabilitate the mandible

with a prosthetic implant for a total of 37 implants. All the

subjects underwent an Orthopantograph due to the ap-

pearance of painful radicular symptoms some time after

the operation.